Skip to main content
  • Original research
  • Open access
  • Published:

Effect of coagulation factor concentrate administration on ROTEM® parameters in major trauma

Abstract

Background

Purified coagulation factor concentrates, such as fibrinogen concentrate (FC) and prothrombin complex concentrate (PCC) are increasingly used as haemostatic therapy for trauma-induced coagulopathy (TIC). The impact of FC and PCC administration on ROTEM parameters among patients with TIC has not been adequately investigated.

Methods

In this retrospective observational study, changes to ROTEM parameters, induced by three different therapeutic interventions, were investigated: patients receiving FC only (FC-group); patients treated with FC and PCC (FC + PCC-group) and patients treated with PCC only (PCC-group).

Results

The study population comprised 96 patients who were predominately male (69 [71.9 %]), median age was 45.0 (26.3–60.0) years, and the median injury severity score was 34.0 (25.0–44.5). Administration of FC resulted in a significant reduction of the clotting time (CT) in both the EXTEM and FIBTEM assays but had no effect on INTEM CT. Clot amplitude (CA) increased significantly in the FIBTEM assay but remained unchanged in the EXTEM and INTEM assays. The combined administration of FC and PCC increased FIBTEM maximum clot firmness (MCF) and normalized EXTEM CT but did not change either INTEM or FIBTEM CT. Following PCC therapy, EXTEM and FIBTEM CT normalized; CA at 10 min after CT measurements decreased significantly in EXTEM, INTEM and FIBTEM.

Conclusions

Administration of FC alone or in combination with PCC resulted in a significant improvement of fibrin polymerisation as measured by an increase in FIBTEM MCF. CT is dependent not only on thrombin generation but also on the availability of substrate (fibrinogen). Accelerated fibrin polymerisation rate results in earlier clot formation and consequently shorter CT. PCC administration normalised EXTEM CT below the upper threshold of 80 s.

This study was performed at the AUVA Trauma Centre Salzburg, Salzburg, Austria.

Background

Trauma induced coagulopathy (TIC), which is accompanied by diffuse uncontrollable microvascular bleeding, is still associated with high mortality rate [1]. According to standard coagulation tests (SCTs), 24–34 % of trauma patients are coagulopathic at emergency room (ER) admission [2, 3]. This early trauma-related coagulopathy is associated with a high risk for massive transfusion and unfavourable outcome [4].

The implementation of a number of treatment strategies, such as permissive hypotension, restrictive fluid administration and aggressive temperature control has proven efficient to reduce trauma-related exsanguination [5]. Furthermore, early and aggressive haemostatic therapy is a cornerstone of modern bleeding management and has been shown to improve survival in coagulopathic trauma patients [6, 7]. In most trauma facilities worldwide, fresh frozen plasma (FFP) is the haemostatic agent used to restore lacking coagulation factors [5, 8, 9]. Due to logistical reasons, FFP transfusion is often associated with substantial time delays and only busy trauma units store pre-thawed plasma [10]. Moreover, whole blood reconstituted from the three components, red blood cells (RBCs), FFP and platelet concentrate (PC), contains substantially lower amounts of coagulation factors, in particular fibrinogen, compared with native whole blood [11]. Furthermore, the ideal ratio of FFP to RBCs is still a matter of debate [10].

An alternative approach for rapid replenishment of lacking coagulation factors is the use of purified coagulation factor concentrates, such as fibrinogen concentrate (FC) or prothrombin complex concentrate (PCC) [1216]. In contrast to FFP, these haemostatic agents contain a well-defined concentration of coagulation proteins, they are immediately available and blood group matching is not necessary [12].

Viscoelastic tests (VETs), most commonly thrombelastography (TEG®, Haemoscope-Haemonetics, Niles, IL) and thromboelastometry (TEM®, Tem Systems Inc., Durham, NC), provide a valuable alternative, or an adjunct, to SCTs in the setting of bleeding, and are increasingly used to diagnose coagulation disturbances following trauma [8, 1719]. VETs provide a comprehensive overview of the whole coagulation process and are assumed to be superior to prothrombin time (PT) or activated thromboplastin time (aPTT) [2022]. Furthermore, VETs can be run as a point of care haemostatic monitoring device, which has been shown to provide measurements much quicker than SCTs [23].

Although some trauma units, in particular in Central Europe, use VET results to guide coagulation therapy based on coagulation factor concentrates, little is known about the extent to which these haemostatic agents change viscoelastic parameters in major bleeding trauma patients. Therefore, we investigated ROTEM® findings before and after administration of FC, PCC or a combination of both.

Methods

Following local ethics committee approval (415-EP/73/197-2013) we performed a retrospective analysis of major trauma patients admitted to the AUVA Trauma Centre, Salzburg between 2008 and 2015. The inclusion criteria were treatment of coagulopathy with coagulation factor concentrates and valid ROTEM results measured before and after administration of coagulation factor concentrates. The maximum time interval between the two measurements was 80 min; sets of analyses were excluded if VET results following therapeutic intervention were obtained later than 80 min after the initial ROTEM analysis. This time frame was chosen as it takes approximately 15 min to obtain the first test results from the ROTEM device. Following this, preparation of the factor concentrates takes approximately 10–15 min. According to the manufacturer’s recommendation, FC should be completely dissolved after a maximum time of 15 min under light circling and avoiding heavy shaking which can cause foam generation. In our institution, FC and sterile water for dissolution is stored at room temperature in the emergency room as low temperature of the carrier fluid can prolong the process of dissolution. The manufacturer recommends that 1 g FC dissolved in 50 ml should be applied with a maximum speed of 5 ml/min or within a minimum of 10 min under normal conditions. However, in severe bleeding FC is administered much faster. In less severe cases, we infuse FC by motor pump with a high administration rate (4 g within 15 min). Infusion rates up to 6 g in 1–2 min have been reported in the literature [24]. PCC is administered intravenously by hand from the syringe connected to the venous access. According to the manufacturer, a maximum infusion rate of 210 U/min should not be exceeded. Thus, it takes approximately 2–3 min for application. Taken together administration of coagulation factor concentrates takes another 10 – 15 min.

Coagulation therapy (algorithm-based)

Coagulation management was based on our institutional protocol for bleeding trauma patients, with treatment determined by the results of VETs (ROTEM®, Tem International, Munich, Germany) [12] Briefly, ROTEM analyses are performed upon emergency room (ER) admission or during initial operative treatment, and if a patient is still coagulopathic during intensive care unit (ICU) stay. FC (Haemocomplettan P, CSL Behring, Marburg, Germany) is considered as first-line therapy in patients with impaired fibrin polymerisation, i.e., a clot amplitude of <7 mm at 10 minutes after CT measurement in the FIBTEM assay (target FIBTEM CA10: 10–12 mm). If clotting time (CT) in the extrinsically activated assay (EXTEM) remains prolonged (>80 s) following FC treatment, PCC is administered. For patients with obviously severe coagulopathy and life-threatening bleeding, immediate treatment with both FC and PCC is preferred. Tranexamic acid (TXA; 15–20 mg/kg bodyweight for patients with injury severity score [ISS] ≥16 and/or severe shock) was incorporated into our treatment protocol in 2011 following publication of the CRASH-2 data [25]. In all cases, the attending physician was free to treat patients at his/her own discretion.

ROTEM measurements were performed before and after three different therapeutic interventions: FC only (FC-group); FC in combination with PCC (FC + PCC-group); and PCC only (PCC-group). Demographic data, laboratory data, trauma severity scores, including ISS, new ISS (NISS), Glasgow coma scale (GCS) score and outcomes data were obtained from the electronic trauma database.

Standard coagulation tests

Citrated blood samples were centrifuged and the following coagulation parameters were assessed: fibrinogen concentration (Clauss Method with electro-mechanical detection using a STA-Compact analyser [Diagnostica Stago S.A.S., Asnières sur Seine, France]; normal range 200–450 mg/dL), PT (measured using a Sysmex XE-2100 [Roche Diagnostics, Mannheim, Germany]; normal range 11.0–16.1 s), aPTT (measured using Sysmex XE-2100; [Roche Diagnostics, Mannheim, Germany]; normal range 23.7–34.9 s) and antithrombin III (AT III; normal range 80–120 %). Haemoglobin and platelet count were determined on a Sysmex SF-3000 (Sysmex Corporation, Kobe, Japan) and base excess was determined on a Roche OMNI® S Blood Gas Analyser (Roche Diagnostics, Mannheim, Germany).

Statistical analysis

For all parameters, normality of the data distribution was tested using the Kolmogorov-Smirnov test. The results are expressed as mean ± standard deviation or median (interquartile range; 25th percentile–75th percentile). Between-group differences were analysed using a paired t-test or Wilcoxon matched-pairs signed-rank test as appropriate. Statistical calculations were performed using GraphPad Prism 5.03 (GraphPad Software, La Jolla, CA). The level of significance was set at P < 0.05.

Results

The study population comprised 96 patients who were predominately male (69; 71.9 %) with a median age of 45.0 (26.3–60.0) years. The median injury severity score (ISS) was 34.0 (25.0–44.5), the median NISS was 41.0 (27.0–50.0), and the median Glasgow coma score (GCS) was 10.0 (5.0–15.0). Demographic and clinical data at ER admission are depicted in Table 1.

Table 1 Clinical characteristics of patients at emergency room admission

One hundred and twenty-five pre-therapy/post-therapy pairs of ROTEM analyses were selected for inclusion in this study. The median time interval between the analyses within each pair was 53.0 (40.0–66.0) minutes. Following FC administration (FC-group), 89 pairs of ROTEM measurements were available for analysis. A further 23 measurements were performed after combined treatment with FC and PCC (FC + PCC-group) and 13 pairs of measurements were completed after therapy with PCC only (PCC-group). Laboratory data at ER admission are outlined in Table 2. Blood transfusion and coagulation therapy within the first 24 h is depicted in Table 3.

Table 2 Blood cell count, standard coagulation tests and blood gas analysis at emergency room admission
Table 3 Blood transfusion and coagulation therapy within the first 24 h

ROTEM parameters before and after therapy with coagulation factor concentrates

A median dose of 4 (3–4) g FC resulted in a significant reduction in EXTEM CT (P < 0.0001) and FIBTEM CT (P = 0.0002). In contrast, FC administration had no effect on INTEM CT, which was significantly prolonged between the two measurements (P < 0.0001; Fig. 1a and Additional file 1: Table S1). Following treatment with FC, a significant increase in alpha angle in both, EXTEM and INTEM assay was observed (P < 0.0001 and P = 0.024). In addition, there was a significant increase in FIBTEM clot amplitude at 10 minutes after CT measurement (CA10; P < 0.0001). In contrast, INTEM CA10 and EXTEM CA10 remained unchanged (Additional file 1: Table S1). Furthermore, treatment with FC resulted in a significant increase in FIBTEM maximum clot firmness (MCF) from 7 to 11 mm (P < 0.0001; Fig. 2a and Additional file 1: Table S1). There was no change in either EXTEM or INTEM MCF.

Fig. 1
figure 1

Changes in thromboelastometric clotting time before and after treatment with coagulation factor concentrates. CT, clotting time; EXTEM, extrinsically activated test; FC, fibrinogen concentrate; INTEM, intrinsically activated test; PCC, prothrombin complex concentrate. Values are presented as box and whiskers plots (Tukey), median (interquartile range). ns = not significant; **P < 0.01; ***P < 0.001; ****P < 0.0001

Fig. 2
figure 2

Changes in thromboelastometric clot amplitude after 10 min running time before and after treatment with coagulation factor concentrates. CA 10, clot amplitude after 10 min running time; EXTEM, extrinsically activated test; FC, fibrinogen concentrate; FIBTEM, extrinsically activated test plus cytochalasin D; INTEM, intrinsically activated test; PCC, prothrombin complex concentrate. Values are presented as box and whiskers plots (Tukey), median (interquartile range). ns = not significant; *P < 0.05; **P < 0.01; ****P < 0.0001

A combined therapy of 5.5 (4–8) g FC and 1200 (1200–1800) units PCC significantly reduced EXTEM CT only (P = 0.0093). In contrast, INTEM CT was prolonged following treatment (Fig. 1b). However, this did not reach statistical significance. Neither EXTEM nor INTEM MCF changed significantly. However, there was a significant, clinically relevant increase in FIBTEM MCF from 4.5 to 8 mm (P = 0.012; Fig. 2b and Additional file 1: Table S1).

Following administration of 1200 (600–1500) units PCC, normalization of both EXTEM CT from 101 s (73.5–171.8) to 77.0 s (64.75–122.5) and FIBTEM CT from 92.0 (56–155.5) to 78 (61.5–117.5) was observed. However, this difference did not reach statistical significance (Fig. 1c). INTEM CT was prolonged, but remained with normal limits (P = 0.151).

CA10 decreased significantly in EXTEM (48.0 to 40.0; P = 0.021), INTEM (45.5 to 38.0; P = 0.029) and FIBTEM CA10 (12.0 to 7.5 mm; P = 0.005) (Fig. 2). MCF decrease in EXTEM and FIBTEM but reached significance in INTEM only. (P = 0.033) (Additional file 1: Table S1).

All ROTEM parameters measured before and after treatment with coagulation factor concentrates are shown in Additional file 1: Table S1.

Discussion

VETs are increasingly used to diagnose coagulopathy and guide haemostatic therapy in many trauma units worldwide [7, 8, 10, 26]. Moreover, coagulation factor concentrates are part of massive transfusion protocols in many European trauma facilities in order to rapidly improve haemostatic capacity in severely bleeding patients [16, 27, 28]. To the best of our knowledge, this is the first study to investigate ROTEM® parameters following administration of coagulation factor concentrates in a trauma population.

As expected FC administration increased both FIBTEM CA10 and MCF in most of the patients studied. In contrast, the detected increases in FIBTEM CA10 and MCF were not followed by significant increases in INTEM and EXTEM CA10 or MCF. Clot strength is dependent on the interaction of activated platelets, the build-up of the fibrin network and activated factor XIII [29]. An explanation for this finding is that a lack of one of these components responsible for clot firmness can potentially be compensated for by another one. In major shock and blood loss both fibrinogen and platelet count decrease, resulting in diminished clot amplitude. An increase in the fibrin component of the clot might counterbalance the decrease in platelet count. In the current study, administration of FC resulted in an increase in FIBTEM CA10 and MCF whereas EXTEM and INTEM CA10 and MCF remained unchanged. The reduction in the EXTEM CA after FC administration is in our opinion a result of ongoing blood loss and consumption. Platelets are the predominate component of the EXTEM CA. If FIBTEM CA increases following FC administration and EXTEM CA remains more or less unchanged, this finding is highly suggestive of diminished platelet count and/or function. Moreover, this finding is a strong hint that FC administration might have a compensatory effect on clot amplitude if platelet count is low. This observation is in agreement with experimental studies proposing a compensatory role of fibrinogen on clot firmness in animals with low platelet count. Velik-Salchner et al. studied the effect of FC or PC administration on blood loss in a porcine model of thrombocytopenia [30]. FC administration in thrombocytopenic pigs resulted in a significantly better increase in median clot firmness than following platelet transfusion (P = 0.0004). Interestingly, thrombocytopenic animals treated with FC showed lower cumulative blood loss and higher survival rate compared with pigs treated with PC only [30].

Moreover, FC infusion not only increased clot firmness but also diminished clot lysis. Improved fibrin polymerization following FC application established clots with higher resistance to profibrinolytic stimuli. This finding is in agreement with data from the MATTERs 2 study, which revealed that inhibition of lysis by TXA resulted in an equal improvement in outcome than transfusion of cryoprecipitate alone. The combination of both substances exhibited the best effect on survival [31].

Importantly, in the current study EXTEM CT shortened significantly following FC administration. By definition, CT is the time from initiation of the coagulation process until a clot amplitude of 2 mm is reached [29]. This finding suggests that if a higher quantity of substrate (e.g., fibrinogen) is available for initial clot formation, EXTEM clot amplitude of 2 mm will be reached more quickly, and consequently CT will be shorter. These results are in line with findings reported by Bolliger et al., who used thromboelastometry to evaluate speed and quality of clot formation in diluted samples supplemented with 50–300 mg/dL fibrinogen. The addition of increasing amounts of fibrinogen led to a concentration-dependent improvement in all thromboelastometric parameters including EXTEM CT [32]. This was also observed by our group in a porcine animal model with in vivo haemodilution and intravenous or intraosseous administration of FC. After administration of FC, EXTEM MCF increased and EXTEM CT was significantly shortened, despite not having added a coagulation factor that enhances thrombin generation [33].

Interestingly, this finding was not detected with INTEM CT. There are several possible explanation for this observation. The endothelial glycocalyx contains significant amounts of heparin-like material [34, 35]. Glycocalyx shedding, as a consequence of shock and hypoperfusion, might discharge these substances resulting in relevant amounts of heparin in the blood stream [36, 37]. A prospective observational study including 77 major trauma patients demonstrated that 5 % of the study cohort displayed evidence of auto-heparinisation [38]. In contrast to EXTEM, the INTEM assay is heparin sensitive [29]. Therefore, the observed prolongation of INTEM CT between the two measurements might be a consequence of heparin release. Furthermore, some PCC preparations contain significant amounts of heparin, which may be a possible explanation for the observed prolongation in INTEM CT following PCC administration. Scharbert et al. reported a concentration-dependent prolongation in CT and clot formation time in non-activated ROTEM tests (NATEM) with a heparin PCC preparation compared with a heparin-free PCC, even at the lowest concentration [39]. In contrast to our study, these experiments were conducted in vitro, without any influence of metabolism of heparin by the liver. However, in the current study we also observed a prolongation in INTEM CT in the FC-group, which did not receive any PCC. A further reason for the observed prolongation of INTEM CT could be related to low factor XII concentrations. Factor XII deficiency is not associated with bleeding diathesis, but might prolong coagulation tests related to contact activation [40].

Administration of PCC alone was associated with reductions in CA in both EXTEM and FIBTEM but a shortening of the CT. PCC primarily augments thrombin generation; as such, it has only limited effects on clot firmness. The detected decrease in CA observed in the current study is presumably a result of ongoing blood loss between the measurements, with consecutive loss of platelets and fibrinogen. Thus, both EXTEM CA and FIBTEM CA decreased but EXTEM CT shortened due to augmented thrombin generation.

Limitations

Several limitations of this study have to be acknowledged. The analyses were not restricted to three groups of patients but to different treatment regimens. This means that the same patient could have received FC and at a later time a combination of FC and PCC or PCC alone, which is in accordance with our goal directed haemostatic algorithm [12]. Therefore, patients were not stratified to an individual treatment group.

As this is a retrospective study, detailed information of intraoperative blood loss, fluid therapy and RBC transfusion between the two measurements was not available. The mean time interval between the two measurements was less than one hour. However, in severely bleeding patients high amounts of fluids and RBCs may have been transfused, which might affect the results. Moreover, artificial colloids interfere with fibrin polymerisation. In our institution, gelatins are the main artificial colloids used. In contrast to hydroxyethyl starches, fibrin polymerization is less disturbed by gelatins and can be compensated for more easily by FC administration [41]. Those patients who received both FC and PCC were considered more coagulopathic than patients who were treated with one component only. Therefore, observed changes between the groups are not comparable. However, it does not necessarily mean that the coagulation factor therapy was less efficient.

Conclusions

The current study showed that administration of FC caused higher amounts of substrate to be available for initial clot formation, resulting in a shortening of the CT in both the EXTEM and FIBTEM assays. Clot amplitude improved in FIBTEM only and remained unchanged in EXTEM and INTEM, which could be attributed to a decrease in concomitant platelet count between the measurements. Combined therapy of FC and PCC resulted in a significant improvement in fibrin polymerization without substantial changes in EXTEM and INTEM clot amplitude. INTEM CT never improved, which might be a result of shock related “auto-heparinisation” or Factor XII deficiency. PCC administration normalised EXTEM CT below the upper threshold of 80 s.

Abbreviations

aPTT:

Activated partial thromboplastin time

AT III:

Antithrombin III

CA10:

Clot amplitude after 10 min

CT:

Clotting time

ER:

Emergency room

FC:

Fibrinogen concentrate

FFP:

Fresh frozen plasma

GCS:

Glasgow coma scale

ICU:

Intensive care unit

ISS:

Injury severity score

MCF:

Maximum clot firmness

NISS:

New injury severity score

PC:

Platelet concentrate

PCC:

Prothrombin complex concentrate

PT:

Prothrombin time

PTI:

Prothrombin time index

RBC:

Red blood cell

SCT:

Standard coagulation test

TXA:

Tranexamic acid

VET:

Viscoelastic test

References

  1. Kauvar DS, Lefering R, Wade CE. Impact of hemorrhage on trauma outcome: an overview of epidemiology, clinical presentations, and therapeutic considerations. J Trauma. 2006;60:S3–11.

    Article  PubMed  Google Scholar 

  2. Brohi K, Singh J, Heron M, Coats T. Acute traumatic coagulopathy. J Trauma. 2003;54:1127–30.

    Article  PubMed  Google Scholar 

  3. Maegele M, Lefering R, Yucel N, Tjardes T, Rixen D, Paffrath T, et al. Early coagulopathy in multiple injury: an analysis from the German Trauma Registry on 8724 patients. Injury. 2007;38:298–304.

    Article  PubMed  Google Scholar 

  4. MacLeod JB, Lynn M, McKenney MG, Cohn SM, Murtha M. Early coagulopathy predicts mortality in trauma. J Trauma. 2003;55:39–44.

    Article  PubMed  Google Scholar 

  5. Duchesne JC, McSwain Jr NE, Cotton BA, Hunt JP, Dellavolpe J, Lafaro K, et al. Damage control resuscitation: the new face of damage control. J Trauma. 2010;69:976–90.

    Article  PubMed  Google Scholar 

  6. Radwan ZA, Bai Y, Matijevic N, del Junco DJ, McCarthy JJ, Wade CE, et al. An emergency department thawed plasma protocol for severely injured patients. JAMA Surg. 2013;148:170–5.

    Article  PubMed Central  PubMed  Google Scholar 

  7. Schöchl H, Nienaber U, Maegele M, Hochleitner G, Primavesi F, Steitz B, et al. Transfusion in trauma: thromboelastometry-guided coagulation factor concentrate-based therapy versus standard fresh frozen plasma-based therapy. Crit Care. 2011;15:R83.

    Article  PubMed Central  PubMed  Google Scholar 

  8. Johansson PI, Sorensen AM, Larsen CF, Windelov NA, Stensballe J, Perner A, et al. Low hemorrhage-related mortality in trauma patients in a Level I trauma center employing transfusion packages and early thromboelastography-directed hemostatic resuscitation with plasma and platelets. Transfusion. 2013;53:3088–99.

    Article  CAS  PubMed  Google Scholar 

  9. Cotton BA, Reddy N, Hatch QM, LeFebvre E, Wade CE, Kozar RA, et al. Damage control resuscitation is associated with a reduction in resuscitation volumes and improvement in survival in 390 damage control laparotomy patients. Ann Surg. 2011;254:598–605.

    Article  PubMed  Google Scholar 

  10. Nascimento B, Callum J, Tien H, Rubenfeld G, Pinto R, Lin Y, et al. Effect of a fixed-ratio (1:1:1) transfusion protocol versus laboratory-results-guided transfusion in patients with severe trauma: a randomized feasibility trial. CMAJ. 2013;185:E583–9.

    Article  PubMed Central  PubMed  Google Scholar 

  11. Ponschab M, Schöchl H, Gabriel C, Süssner S, Cadamuro J, Haschke-Becher E, et al. Haemostatic profile of reconstituted blood in a proposed 1:1:1 ratio of packed red blood cells, platelet concentrates and four different plasma preparations. Anaesthesia. 2015. In press.

  12. Schöchl H, Schlimp CJ, Voelckel W. Potential value of pharmacological protocols in trauma. Curr Opin Anaesthesiol. 2013;26:221–9.

    Article  PubMed  Google Scholar 

  13. Theusinger OM, Spahn DR, Ganter MT. Transfusion in trauma: why and how should we change our current practice? Curr Opin Anaesthesiol. 2009;22:305–12.

    Article  PubMed  Google Scholar 

  14. Ziegler B, Schimke C, Marchet P, Stogermuller B, Schöchl H, Solomon C. Severe pediatric blunt trauma--successful ROTEM-guided hemostatic therapy with fibrinogen concentrate and no administration of fresh frozen plasma or platelets. Clin Appl Thromb Hemost. 2013;19:453–9.

    Article  PubMed  Google Scholar 

  15. Grassetto A, Fullin G, Cerri G, Simioni P, Spiezia L, Maggiolo C. Management of severe bleeding in a ruptured extrauterine pregnancy: a theragnostic approach. Blood Coagul Fibrinolysis. 2014;25:176–9.

    Article  PubMed  Google Scholar 

  16. David JS, Godier A, Dargaud Y, Inaba K. Case scenario: management of trauma-induced coagulopathy in a severe blunt trauma patient. Anesthesiology. 2013;119:191–200.

    Article  PubMed  Google Scholar 

  17. Schöchl H, Schlimp CJ. Trauma bleeding management: the concept of goal-directed primary care. Anesth Analg. 2013. doi: 10.1213/ANE.0b013e318270a6f7.

  18. Kashuk JL, Moore EE, Wohlauer M, Johnson JL, Pezold M, Lawrence J, et al. Initial experiences with point-of-care rapid thrombelastography for management of life-threatening postinjury coagulopathy. Transfusion. 2012;52:23–33.

    Article  PubMed  Google Scholar 

  19. Holcomb JB, Minei KM, Scerbo ML, Radwan ZA, Wade CE, Kozar RA, et al. Admission rapid thrombelastography can replace conventional coagulation tests in the emergency department: experience with 1974 consecutive trauma patients. Ann Surg. 2012;256:476–86.

    Article  PubMed  Google Scholar 

  20. Davenport R, Manson J, De’Ath H, Platton S, Coates A, Allard S, et al. Functional definition and characterization of acute traumatic coagulopathy. Crit Care Med. 2011;39:2652–8.

    PubMed Central  PubMed  Google Scholar 

  21. Johansson PI. Emerging treatment strategies for trauma-induced coagulopathy. Br J Surg. 2012;99 Suppl 1:51.

    Article  PubMed  Google Scholar 

  22. Haas T, Fries D, Tanaka KA, Asmis L, Curry NS, Schöchl H. The usefulness of standard plasma coagulation tests in the management of perioperative coagulopathic bleeding – Is there any evidence? Brit J Anaest. 2014. In press.

  23. Haas T, Goobie S, Spielmann N, Weiss M, Schmugge M. Improvements in patient blood management for pediatric craniosynostosis surgery using a ROTEM((R)) -assisted strategy - feasibility and costs. Paediatr Anaesth. 2014;24:774–80.

    Article  PubMed Central  PubMed  Google Scholar 

  24. Solomon C, Pichlmaier U, Schoechl H, Hagl C, Raymondos K, Scheinichen D, et al. Recovery of fibrinogen after administration of fibrinogen concentrate to patients with severe bleeding after cardiopulmonary bypass surgery. Br J Anaesth. 2010;104:555–62.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  25. Shakur H, Roberts I, Bautista R, Caballero J, Coats T, Dewan Y, et al. Effects of tranexamic acid on death, vascular occlusive events, and blood transfusion in trauma patients with significant haemorrhage (CRASH-2): a randomised, placebo-controlled trial. Lancet. 2010;376:23–32.

    Article  CAS  PubMed  Google Scholar 

  26. Yin JY, Zhao Z, Li Y, Wang J, Yao D, Zhang S, et al. Goal-directed transfusion protocol via thrombelastography in patients with abdominal trauma: a retrospective study. World J Emerg Surg. 2014;9:28.

    Article  PubMed Central  PubMed  Google Scholar 

  27. Schöchl H, Nienaber U, Hofer G, Voelckel W, Jambor C, Scharbert G, et al. Goal-directed coagulation management of major trauma patients using thromboelastometry (ROTEM)-guided administration of fibrinogen concentrate and prothrombin complex concentrate. Crit Care. 2010;14:R55.

    Article  PubMed Central  PubMed  Google Scholar 

  28. Grassetto A, De Nardin M, Ganzerla B, Geremia M, Saggioro D, Serafini E, et al. ROTEM(R)-guided coagulation factor concentrate therapy in trauma: 2-year experience in Venice, Italy. Crit Care. 2012;16:428.

    PubMed Central  PubMed  Google Scholar 

  29. Schöchl H, Voelckel W, Grassetto A, Schlimp CJ. Practical application of point-of-care coagulation testing to guide treatment decisions in trauma. J Trauma Acute Care Surg. 2013;74:1587–98.

    Article  PubMed  Google Scholar 

  30. Velik-Salchner C, Haas T, Innerhofer P, Streif W, Nussbaumer W, Klingler A, et al. The effect of fibrinogen concentrate on thrombocytopenia. J Thromb Haemost. 2007;5:1019–25.

    Article  CAS  PubMed  Google Scholar 

  31. Morrison JJ, Ross JD, Dubose JJ, Jansen JO, Midwinter MJ, Rasmussen TE. Association of cryoprecipitate and tranexamic acid with improved survival following wartime injury: findings from the MATTERs II Study. JAMA Surg. 2013;148:218–25.

    Article  CAS  PubMed  Google Scholar 

  32. Bolliger D, Szlam F, Molinaro RJ, Rahe-Meyer N, Levy JH, Tanaka KA. Finding the optimal concentration range for fibrinogen replacement after severe haemodilution: an in vitro model. Br J Anaesth. 2009;102:793–9.

    Article  CAS  PubMed  Google Scholar 

  33. Schlimp CJ, Solomon C, Keibl C, Zipperle J, Nürnberger S, Öhlinger W, et al. Recovery of fibrinogen concentrate after intraosseous application is equivalent to the intravenous route in a porcine model of hemodilution. J Trauma Acute Care Surg. 2014;76:1235–42.

    Article  CAS  PubMed  Google Scholar 

  34. Becker BF, Chappell D, Bruegger D, Annecke T, Jacob M. Therapeutic strategies targeting the endothelial glycocalyx: acute deficits, but great potential. Cardiovasc Res. 2010;87:300–10.

    Article  CAS  PubMed  Google Scholar 

  35. Reitsma S, Slaaf DW, Vink H, van Zandvoort MA, oude Egbrink MG. The endothelial glycocalyx: composition, functions, and visualization. Pflugers Arch. 2007;454:345–59.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  36. Senzolo M, Coppell J, Cholongitas E, Riddell A, Triantos CK, Perry D, et al. The effects of glycosaminoglycans on coagulation: a thromboelastographic study. Blood Coagul Fibrinolysis. 2007;18:227–36.

    Article  CAS  PubMed  Google Scholar 

  37. Rehm M, Bruegger D, Christ F, Conzen P, Thiel M, Jacob M, et al. Shedding of the endothelial glycocalyx in patients undergoing major vascular surgery with global and regional ischemia. Circulation. 2007;116:1896–906.

    Article  CAS  PubMed  Google Scholar 

  38. Ostrowski SR, Johansson PI. Endothelial glycocalyx degradation induces endogenous heparinization in patients with severe injury and early traumatic coagulopathy. J Trauma Acute Care Surg. 2012;73:60–6.

    Article  CAS  PubMed  Google Scholar 

  39. Scharbert G, Thaler U, Weilnbock C, Wetzel L, Kozek-Langenecker S. Heparin-induced effects of prothrombin complex concentrates in thromboelastometry. Wien Klin Wochenschr. 2012;124:320–5.

    Article  CAS  PubMed  Google Scholar 

  40. Renne T, Schmaier AH, Nickel KF, Blomback M, Maas C. In vivo roles of factor XII. Blood. 2012;120:4296–303.

    Article  PubMed Central  CAS  PubMed  Google Scholar 

  41. Schlimp CJ, Cadamuro J, Solomon C, Redl H, Schochl H. The effect of fibrinogen concentrate and factor XIII on thromboelastometry in 33 % diluted blood with albumin, gelatine, hydroxyethyl starch or saline in vitro. Blood Transfus. 2013;11:510–7.

    PubMed Central  PubMed  Google Scholar 

Download references

Acknowledgements

Editorial assistance with manuscript preparation was provided by medical writers at Meridian HealthComms (Plumley, UK), funded by CSL Behring.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Herbert Schöchl.

Additional information

Competing interests

HS has received research support, travel funding and speaker fees from TEM® Innovations GmbH, Munich, Germany, and CSL Behring and is a board member of the “Coagulation Task Force” in the Austrian Society for Anaesthesiology, Intensive Care and Resuscitation. CJS has received research support, travel funding and speaker fees from CSL Behring and research support from TEM® Innovations GmbH, Munich, Germany and is a board member of the “Coagulation Task Force” in the Austrian Society for Anaesthesiology, Intensive Care and Resuscitation. MPo has received research support from TEM International and from CSL Behring. MPa and WV have no conflicts of interest to declare.

Authors’ contribution

MPo: data collection and analysis, writing of the paper; HS: data collection and analysis, writing of the paper; WV: data interpretation and writing of the paper; MPa: data collection and analysis; CJS: data analysis and writing of the paper. All authors read and approved the final manuscript.

Additional file

Additional file 1: Table S1.

ROTEM parameters measured before and after treatment with coagulation factor concentrates. (DOCX 28 kb)

Rights and permissions

Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ponschab, M., Voelckel, W., Pavelka, M. et al. Effect of coagulation factor concentrate administration on ROTEM® parameters in major trauma. Scand J Trauma Resusc Emerg Med 23, 84 (2015). https://doi.org/10.1186/s13049-015-0165-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13049-015-0165-4

Keywords