Table 4 Coagulation analyses by RoTEM converted to ratios of baseline values

From: Changes in fibrinogen availability and utilization in an animal model of traumatic coagulopathy

   

Base line

0 minutes

30 minutes

60 minutes

ExTEM

CT

TS

1.0 (0.0)

1.18 (0.49)

1.0 (0.58)

0.77 (0.27)

  

T

1.0 (0.0)

1.16 (0.29)

1.02 (0.49)

0.86 (0.26)

  

S

1.0 (0.0)

 

1.12 (0.27)

1.04 (0.28)

  

C

1.0 (0.0)

 

0.79 (0.43)

0.91 (0.32)

 

MCF

TS

1.0 (0.0)

1.0 (0.03)

0.97 (0.02)*

0.98 (0.02) †

  

T

1.0 (0.0)

1.0 (0.01)

0.95 (0.10)

0.97 (0.02)

  

S

1.0 (0.0)

 

0.95 (0.03)

0.95 (0.02)*†

  

C

1.0 (0.0)

 

1.02 (0.01)

1.01 (0.01)

FibTEM

CT

TS

1.0 (0.0)

0.91 (0.32)

0.64 (0.29)*†

0.66 (0.15)*†

  

T

1.0 (0.0)

0.95 (0.63)

1.08 (0.67)

0.97 (0.55)

  

S

1.0 (0.0)

 

1.14 (0.30)†

0.91 (0.11)†

  

C

1.0 (0.0)

 

0.79 (0.43)

0.91 (0.32)

 

MCF

TS

1.0 (0.0)

1.19 (0.30)

1.89 (0.81)*†

1.59 (0.39)*†

  

T

1.0 (0.0)

1.45 (0.61)

0.93 (0.49)

1.15 (0.32)

  

S

1.0 (0.0)

 

0.88 (0.07)*†

0.93 (0.13)†

  

C

1.0 (0.0)

 

1.01 (0.16)

0.98 (0.09)

  1. TS Trauma Shock group, T Trauma group, S Shock group, C Control group, CT Clotting time, MCF maximum clot firmness, Values are given as mean ratios of baseline values (SD).