Table 2 Selected linear regression models.

From: Systemic central venous oxygen saturation is associated with clot strength during traumatic hemorrhagic shock: A preclinical observational model

Independent Variable

F Ratio

p value

Outcome Variable

Whole Model R2

Whole Model p value

ScvO2

57.7

0.083

Clot Strength (MA) at OD = 80 ml/kg

0.99

0.032

MA (baseline)

513

0.028

   

Fibrinogen

44.7

0.095

   

Hematocrit

5.6

0.113

   

ScvO22

1.5

0.44

   

ScvO2

508.5

0.028

Delta Clot Strength (MA)

0.99

0.029

Fibrinogen

830.6

0.022

   

Platelet count

52

0.088

   

ScvO22

338.2

0.035

   

(ScvO2*Platelet count)

141.9

0.053

   
  1. Summary of 2 linear regression models selected by forward stepwise variable selection per Materials and Methods. Each overall model was highly predictive of the MA measured during shock (OD = 80 ml/kg) or the change (Delta) in MA from baseline to shock. Fibrinogen and ScvO2 played important roles within each selected model.